Design guide – MicroE Mercury II 6000V User Manual
Page 29

Page 7
Design Guide
B3.0
Verify the tolerances of the scale's mounting 
surface given in the Interface Drawing.
B3.1
Verify the dimensions of the scale benching 
edge (groove or straight edge) given in the 
Interface Drawing.
B3.2
Calculate the length of PurePrecision
™
Tape Scale
required for your application using the formula
ML + 40 mm (ML - Measuring Length). Refer to 
the Interface Drawing.
B3.3
In order to install the tape scale against a straight
edge, either the Applicator Tool or hands can 
be used. 
It is recommended to use the Applicator Tool for all
installations against a straight edge and highly
recommended for lengths greater than 250mm 
(10 inches).
B3.4
In the case where the tape scale is to be installed 
in a 6mm-wide groove, it has to be done by hand
only. The Applicator Tool is not compatible with a
6mm groove. Refer to the Interface Drawing.
B3.5
If machining the mounting surface is undesirable, 
or not possible, a temporary straight edge can be
used that meets the dimensions and tolerances
specified in the Interface Drawing.
Section B - PurePrecision
™
Tape Scale Installation
Two kinds of temporary straight edge can be used -
• Type I -
Temporary Straight Edge of thickness 
0.76 ± 0.05 mm (0.030 ± 0.002 inches). 
Refer to the Interface Drawing for additional 
dimensional requirements. A steel rule may be 
one of the options for this type of temporary 
straight edge. 
NOTE:
The guide edge of the applicator tool (the edge 
that comes in contact with the mounting surface 
reference edge during installation of tape scale) 
for this application is located on its bottom 
surface. See Section B6.2 for further information. 
• Type II -
Temporary straight edge with minimum 
thickness 9.53mm (0.375 inches). Refer to the 
Interface Drawing for additional dimensional 
requirements. 
NOTE:
The guide edge of the Applicator Tool for this 
application is located on the outside surface. 
See Section B6.2 for further information. 
The tape scale will be offset from the temporary 
straight edge for this application. 
When using Type II temporary straight edge, 
another temporary benching surface may be 
required to install the index and limit markers 
due to the offset.