beautypg.com

Power – Measurement Computing SC-1608 Series User Manual

Page 27

background image

SC-1608 Series User's Guide

Specifications

27

Power

Table 5. Power specifications

Parameter

Condition

Specification

External power input
connectors (Note 7)

J1: barrel type

J2: 2-pole terminal block, (16 AWG to 30 AWG)

External power input voltage
range (Note 8)

12V, ±5%

External power supply current

25 mA typical (Note 9)
1700 mA max, including all external loading

External power supply
(included)

MCC p/n PS-12V30WEPS

+12 V DC, 30 Watt, 5% regulation

+VO output voltage range

User I/O connector J35, pin 29

4.50 V min to 5.25 V max

+VO output current

10 mA max

Power LED

3V < V

ext

< 15 V: LED is ON

V

ext

> 15 V: LED OFF (power fault)

Power ON sequence (Note 10)

Arbitrary; either the SCC-8-8-2 or the OEM DAQ
board can be powered on first.

Note 7:

The SCC-8-8-2 can be powered from either of the external power connectors J1 or J2. Do not
attempt to apply power to both external power connectors simultaneously.

Note 8:

This specification applies to the actual voltage level present at the input to the external power
connector (J1 or J2) of the SCC-8-8-2, as any significant loading of the external power supply will
cause a voltage drop across the power supply cable.

Note 9:

This is the total quiescent current requirement for the device, and does not include any potential
loading of the 8B modules, SSR modules, digital I/O bits, or +VO terminal.

Note 10:

To prevent digital inputs from floating, both the SCC-8-8-2 and the OEM DAQ board should be
powered off while they are being assembled together.

Note 11:

When using a USB-1608G-OEM-Series board, the total current available for 8B analog I/O modules
and SSR digital I/O modules is 1612 mA, maximum.
When using the E-1608-OEM, the total current available for 8B analog I/O modules and SSR digital
I/O modules is 1292 mA, maximum. For example, this current limitation would restrict the number
of 8B38 strain gage modules that can be installed on the SC-1608-2AO-ENET to six (when SSR
modules are installed), or seven (when no SSR modules are installed). Refer to the SC-1608 Series
User's Guide for details.