beautypg.com

Standard 2 of 5, Trioptic – Datalogic Scanning Pegaso User Manual

Page 119

background image

Bar Code Parameters

Product Reference Guide

F-11

Standard 2 of 5

Enter 1 for On

and 0 for Off.

Enable

Enables/disables the Standard 2 of 5 symbol-
ogy.

0200

On / Off

Off

On

Off

Enable
Aggressive
Decoding

Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.

0201

On / Off

Off

On

Off

Enable
Checksum

Requires the use of checksum characters to
verify a bar code

0202

On / Off

Off

Off

Off

Send Check-
sum

Instructs the terminal to include the checksum
in the label transmission.

0203

On / Off

Off

Off

Off

Use 2-bar
Start/Stop

Allows the terminal to recognize labels that
are printed using only two bars for start/stop
characters.

0204

On / Off

Off

Off

Off

Minimum
Label Length

Set the minimum label length to be less than
or equal to maximum label length.

0220

01 - 50

01

01

06

Maximum
Label Length

This feature specifies the maximum allowable
length of a Standard 2 of 5 label. The length
includes check and data characters. Maximum
Label Length should be greater than or equal
to Minimum Label Length.

0221

01 - 50

01

50

10

Read Verifi-
cation

Sets the number of times a label must be read
before it is transmitted.

0222

01 - 04

01

02

01

User ID

Specifies the symbology identifier (if any) that
is sent when parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero (null) is
used to indicate that an identifier is not to be
sent for the symbology.

0223

Any single

ASCII

character

(00 = Off)

'F'

'F'

'F'

Trioptic

Enter 1 for On

and 0 for Off.

Enable

Enables/disables the Trioptic symbology.

0108

On / Off

Off

On

Off

Enable
Aggressive
Decoding

Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.

0109

On / Off

Off

On

Off

Read Verifi-
cation

Sets the number of times a label must be read
before it is transmitted.

0124

01 - 04

01

02

01

Code Parameter/ Description

I.D. #

Acceptable

Input

Defaults

Min

Max

Factory