Matrix 2 of 5 – Datalogic Scanning Pegaso User Manual
Page 116

Programming Parameters
F-8
Pegaso™ Industrial PDA with Windows
®
CE
User ID
Specifies the symbology identifier (if any) that
is sent by the decoder when parameter Send
Code ID (Index 0025) is set to 3. "ASCII" code
zero (null) is used to indicate that an identifier
is not to be sent for the symbology.
022B
Any single
ASCII
character
(00 = Off)
'B'
'B'
'B'
Matrix 2 of 5
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the Matrix 2 of 5 symbology.
0208
On / Off
Off
On
Off
Enable
Aggressive
Decoding
Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.
0209
On / Off
Off
On
Off
Enable
Checksum
Requires the use of checksum characters to
verify a bar code.
020A
On / Off
Off
Off
Off
Send Check-
sum
Instructs the terminal to include the checksum
in the label transmission.
020B
On / Off
Off
Off
Off
Minimum
Label Length
Set the minimum label length to be less than
or equal to maximum label length.
0224
01 - 50
01
01
06
Maximum
Label Length
This feature specifies the maximum allowable
length of a Matrix 2 of 5 label. The length
includes check and data characters. Maximum
Label Length should be greater than or equal
to Minimum Label Length.
0225
01 - 50
01
50
10
Read Verifi-
cation
Sets the number of times a label must be read
before it is transmitted.
0226
01 - 04
01
02
01
User ID
Specifies the symbology identifier (if any) that
is sent by the decoder when parameter Send
Code ID (Index 0025) is set to 3. "ASCII" code
zero (null) is used to indicate that an identifier
is not to be sent for the symbology.
0227
Any single
ASCII
character
(00 = Off)
'D'
'D'
'D'
MSI
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the MSI symbology.
0608
On / Off
Off
On
Off
Enable
Aggressive
Decoding
Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.
0609
On / Off
Off
On
Off
Require
2 Check Dig-
its
An MSCI label must contain 2 check digits.
060A
On / Off
Off
Off
Off
Code Parameter/ Description
I.D. #
Acceptable
Input
Defaults
Min
Max
Factory