Code 128 – Datalogic Scanning Pegaso User Manual
Page 113

Bar Code Parameters
Product Reference Guide
F-5
Maximum
Label Length
This feature specifies the maximum allowable
length of a Code 93 label. The length includes
check and data characters. Maximum Label
Length should be greater than or equal to Min-
imum Label Length.
0421
01 - 50
01
50
20
Read Verifi-
cation
Sets the number of times a label must be read
before it is transmitted.
0422
01 - 04
01
02
01
User ID
Specifies the symbology identifier (if any) that
is sent when parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero (null) is
used to indicate that an identifier is not to be
sent for the symbology.
0423
Any single
ASCII
character
(00 = Off)
'L'
'L'
'L'
Code 128
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the Code 128 symbology.
0408
On / Off
Off
On
On
Enable
Aggressive
Decoding
Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.
0409
On / Off
Off
On
Off
Enable UCC/
EAN-128
Instructs the decoder to recognize UCC-128
versions of Code 128 labels and process them
differently by changing the Code ID, and
replacing each occurrence of the FNC1 char-
acter with GS ("ASCII" 29) characters.
040C
On / Off
Off
On
Off
ISBT Concat-
enation
Instructs the decoder to concatenate Code
128 labels conforming to the ISBT 128 stan-
dard.
040E
On / Off
Off
Off
Minimum
Label Length
Set the minimum label length to be less than
or equal to maximum label length.
0424
01 - 50
01
01
02
Maximum
Label Length
This feature specifies the maximum allowable
length of a Code 128 label. The length
includes check and data characters. Maximum
Label Length should be greater than or equal
to Minimum Label Length.
0425
01 - 50
01
50
20
Read Verifi-
cation
Sets the number of times a label must be read
before it is transmitted.
0426
01 - 04
01
02
01
User ID
Specifies the symbology identifier (if any) sent
when parameter Send Code ID (Index 0025)
is set to 3. "ASCII" code zero (null) is used to
indicate that an identifier is not to be sent for
the symbology.
0427
Any single
ASCII
character
(00 = Off)
'K'
'K'
'K'
Code Parameter/ Description
I.D. #
Acceptable
Input
Defaults
Min
Max
Factory