Code 39, Code 93 – Datalogic Scanning Pegaso User Manual
Page 112

Programming Parameters
F-4
Pegaso™ Industrial PDA with Windows
®
CE
Code 39
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the Code 39 symbology.
0100
On / Off
Off
On
On
Enable
Aggressive
Decoding
Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.
0101
On / Off
Off
On
Off
Enable
Checksum
Requires the use of checksum characters to
verify a bar code.
0102
On / Off
Off
Off
Off
Send Check-
sum
Instructs the terminal to include the checksum
in the label transmission.
0103
On / Off
Off
Off
Off
Full ASCII
Mode
Supports the entire ASCII character set by
replacing various encoded ASCII characters
with their corresponding "ASCII" equivalents.
0105
On / Off
Off
On
On
Minimum
Label Length
Set the minimum label length to be less than
or equal to maximum label length.
0120
01 - 50
01
01
01
Maximum
Label Length
This feature specifies the maximum allowable
length of a Code 39 label. The length includes
check and data characters. Maximum Label
Length should be greater than or equal to Min-
imum Label Length.
0121
01 - 50
01
50
20
Read Verifi-
cation
Sets the number of times a label must be read
before it is transmitted.
0122
01 - 04
01
02
01
User ID
Specifies the symbology identifier (if any) that
is sent when parameter Send Code ID (Index
0025) is set to 3. "ASCII" code zero (null) is
used to indicate that an identifier is not to be
sent for the symbology.
0123
Any single
ASCII
character
(00 = Off)
'C'
'C'
'C'
Code 93
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the Code 93 symbology.
0400
On / Off
Off
On
Off
Enable
Aggressive
Decoding
Enables more aggressive decoding algorithms
to be used in order to scan hard to read
labels.
0401
On / Off
Off
On
Off
Minimum
Label Length
Set the minimum label length to be less than
or equal to maximum label length.
0420
01 - 50
01
01
02
Code Parameter/ Description
I.D. #
Acceptable
Input
Defaults
Min
Max
Factory