beautypg.com

Firing parameters – Ivoclar Vivadent IPS InLine System User Manual

Page 76

background image

76

Firing parameters

IPS InLine

PoM

Press-on-Metal Keramik

T

°C/°F

B

°C/°F

S

min

t

°C/°F/min

H

min

V

1

°C/°F

V

2

°C/°F

1

st

+ 2

nd

Opaquer firing, powder opaquer

960/1760

403/757

4

100/180

2

450/842

959/1758

1

st

+ 2

nd

Opaquer firing, paste opaquer

930/1706

403/757

6

100/180

2

450/842

929/1704

Touch-Up firing

840/1544

403/757

4

60/108

1

450/842

839/1542

Shade/Stains firing

800/1472

403/757

6

60/108

1

450/842

839/1542

Glasur-Brand

800/1472

403/757

6

60/108

2

450/842

839/1542

Add-On after Glaze firing (690 °C/1274 °F)

690/1274

403/757

4

60/108

1

450/842

689/1272

T = Firing temperature °C/°F

B = Stand-by temperature °C/°F

S = Closing time in minutes

t

= Heating rate °C/°F/min

H = Holding time

V

1

= Vacuum on temperature °C/°F

V

2

= Vacuum off temperature °C/°F

these firing parameters are guidance values. they are valid for the Programat furnaces from Ivoclar vivadent.
Deviations (approx. +/- 10 °C/18 °F) may occur:
– Depending on the furnace generation.
– If ceramic furnaces from other manufacturers are used.
– In case of regional differences in the power supply or if several electrical devices are operatated on the same circuit.