beautypg.com

Inline, Accurate press-on technique – Ivoclar Vivadent IPS InLine System User Manual

Page 47

background image

47

2. framework design for pressed-on ceramic shoulders

With pressed-on ceramic shoulders, make sure that the framework rather than the veneer is supported by the prepared
tooth. The framework is thus reduced exactly to the inner edge of the chamfer or shoulder preparation to achieve
functional support of the framework on the preparation. Excellent accuracy of fit on the preparation is essential to ensure
that the shoulder material may not reach the inner aspects of the framework during subsequent application.

wrong

correct

Single connector width

= single stability

Double the width of the
connector

= double the stability

Double the height of the
connector with single width

= eightfold stability

3. framework stability

The dimensions and shape of the interdental connector surfaces significantly influence the stability of the restoration
during processing as well as the clinical long-term success after incorporation. Therefore, the dimensions of the interdental
connector surface must be designed in accordance with the alloy used (take the 0.2% proof stress into account)! The
thermal behaviour of the selected alloy during processing has to be considered when designing the framework.