beautypg.com

Wax-up – Ivoclar Vivadent IPS InLine System User Manual

Page 57

background image

57

IPS
InLine

PoM

– Accurate Press-On Technique

Wax-up

After the fabrication of the model with detachable segments and the preparation of the dies, the restoration is contoured.
Use only organic waxes for contouring, since they fire without leaving residue.
– Weigh the metal framework coated with opaquer and record the weight. The weight is used to determine the wax

weight after contouring.

.

– Subsequently, secure the framework on the model in the proper position and wax the margins first.
– Fabricate a fully anatomical wax-up as usual. Observe a layer thickness of at least 0.8 mm. Make sure not to exceed a

thickness of 1.5 mm in order to ensure optimum shade reproduction.

– Observe a wax thickness of at least 0.8 mm to avoid incomplete press results.

Fully anatomical wax-up on the metal framework. Observe the minimum layer thicknesses at all times.