beautypg.com

Dentcisal firing – Ivoclar Vivadent IPS InLine System User Manual

Page 23

background image

23

2

nd

dentcisal firing

Finish and thoroughly clean the restoration. Clean under running water or with the steam jet. Blasting the restoration with
Al

2

O

3

(type 50) at 1 bar (15 psi) pressure is only necessary if there is superficial contamination after cleaning. Thoroughly

dry the restoration and complete the missing areas. Pay special attention to interdental spaces as well as contact points.
Place the completely layered restoration on the firing tray and ensure adequate support. The firing tray with the restoration
should only be placed in the firing chamber once the furnace head is completely open and the beeper has sounded. Use
the firing parameters stipulated below to fire the restoration.

firing parameters 2

nd

denticisal firing

T

°C/°F

B

°C /°F

S

min

t

°C/°F/min

H

min

V

1

°C/°F

V

2

°C/°F

900/1652

403/757

4

60/108

1

450/842

899/1650

Supplementing the restoration with Dentcisal material

Final design of the occlusal surface

Important

• Use distilled water to rewet the mixed or even already applied layering material.
• The firing tray with the restoration should only be placed in the firing chamber and removed from it once

the furnace head is completely open and the beeper has sounded.

IPS
InLine

One

One-Layer Metal-Ceramic