Adjustments with IPS InLine PoM touch-Up
For minor shape adjustments, such as incompletely pressed margins or occlusal surfaces, the 7 Touch-Up materials are
available in the respective ingot shade. The Touch-Up materials must only be used for metal-
supported IPS InLine PoM restorations.
Processing
– The restoration must be free of dirt and grease prior to adjustment. For that
purpose, clean the restoration thoroughly with a steam jet.
– Apply the IPS InLine PoM Touch-Up material mixed with IPS InLine System Build-Up
Liquid on the missing, cleaned areas using a brush and slightly blot with an absorbent
cloth.
– Place the restoration on the firing tray and fire it.
– Next, finish the restoration or apply second Touch-Up adjustments and fire with the
same parameters.
firing parameters for IPS InLine PoM touch-Up
T
°C/°F
B
°C/°F
S
min
t
°C/°F/min
H
min
V
1
°C/°F
V
2
°C/°F
840/1544
403/757
4
60/108
1
450/842
839/1542
Bridge with sprues
Adjustment with IPS InLine PoM Touch Up
Special attention is required for separating the palatal metal retention pin. Make sure to separate and polish the retention pin carefully after glazing without creating too much heat.
Separating / finishing
After separation of the sprues and smoothing of the attachment points, the pressed object is fitted to the master model.
For that purpose, the usual rotary instruments (as those used for IPS Empress) are used (without pressure and over-
heating). After that, carefully sandblast the restoration. Finally, clean the restoration under running water or with steam.