Ivoclar Vivadent IPS InLine System User Manual
Page 64

64
Press parameters for IPS InLine PoM ingots in the IPS Investment ring System 300 g
Investment Ring
300 g
B
°C/°F
T
°C/°F
H
min
t
°C/°F/min
V
1
°C/°F
V
2
°C/°F
N / E
300 g
EP 500 / V 2.9
700/1292
960/1760
40
60/108
500/932
960/1760
Program 31–51
eP 600 /
eP 600 combi
700/1292
950/1742
40
60/108
500/932
950/1742
50 µm/min.*
Programat eP 3000 /
Programat eP 5000
700/1292
950/1742
40
60/108
500/932
950/1742
50 µm/min.*
*Important: If you enter the program manually, observe the abort criterion.
Provide a
cold
IPS One-Way Plunger and
cold
IPS InLine
PoM ingots in the desired shade.
Insert the
cold
IPS InLine PoM ingots with the imprint fac-
ing upwards into the
hot
investment ring.
Place the
cold
IPS One-Way Plunger 300 g in the
hot
investment ring.
Place the
hot
and completed investment ring in the centre
of the
hot
press furnace using the IPS Investment Ring
Tongs
Press START to start the selected program.
Once the press program is completed, place the hot invest-
ment ring on the cooling grid using the Investment Ring
Tongs and allow it to cool to room temperature.
IPS One-Way Plunger 300 g for IPS Investment ring System 300 g