58

On the IPS Investment Ring Base, always attach sprues in the direction of flow of the ceramic and to the thickest part of the restoration.

Sprueing

The diameter for the sprues is 3 mm. For multi-unit bridges, each bridge unit must be provided with a sprue. Always attach
the sprues in the direction of flow of the ceramic and at the thickest part of the wax-up so that smooth flowing of the
viscous ceramic during pressing is enabled. Depending on the number of objects to be invested, either the 100 g, 200 g, or
300 g IPS Investment Ring System is selected. Bridges must only be pressed in the 200 g or 300 g Investment Ring System.
The following sprueing guidelines have to be observed:

ring Base

Wax wire Ø

Length of the wax wire

Length of the wax wire including
waxed-up object

Sprue attachment point at the
waxed-up object
Sprue angle to the waxed-up
object

Sprue angle to the ring base

design of the attachment points

distance between the objects

distance to the silicone ring

Important

Single crowns, Bridges

100 g, 200 g, 300 g

3 mm

min. 3 mm, max. 10 mm

max. 15–16 mm

thickest part of the wax-up; every bridge unit

in the direction of flow of the ceramic;

observe the cusp angulation

45–60°

rounded,

no angles or edges

min. 3 mm

Crowns: min. 10 mm; Bridges: 58 mm

Larger bridges may also be placed in the

centre of the investment ring.