Inline, Firing parameters, Conventional metal-ceramic – Ivoclar Vivadent IPS InLine System User Manual
Page 74

74
T = Firing temperature °C/°F
B = Stand-by temperature °C/°F
S = Closing time in minutes
t
➚
= Heating rate °C/°F/min
H = Holding time
V
1
= Vacuum on temperature °C/°F
V
2
= Vacuum off temperature °C/°F
Firing Parameters
IPS InLine
Conventional metal-ceramic
T
°C/°F
B
°C/°F
S
min
t
°C/°F/min
H
min
V
1
°C/°F
V
2
°C/°F
1
st
+ 2
nd
Opaquer firing, powder opaquer
960/1760
403/757
4
100/180
2
450/842
959/1758
1
st
+ 2
nd
Opaquer firing / Gingiva, paste opaquer
930/1706
403/757
6
100/180
2
450/842
929/1704
1
st
+ 2
nd
Margin firing
930/1706
403/757
4
60/108
1
450/842
929/1704
1
st
Dentin and Incisal firing / Gingiva
910/1670
403/757
4
60/108
1
450/842
909/1668
2
nd
Dentin and Incisal firing / Gingiva
900/1652
403/757
4
60/108
1
450/842
899/1650
Margin Add-On firing
900/1652
403/757
4
60/108
1
450/842
899/1650
Corrective firing after Dentin and Incisal firing, Add-On 860/1580
403/757
4
60/108
1
450/842
859/1578
Shade / Stains firing
850/1562
403/757
6
60/108
1
450/842
849/1560
Glaze firing
850/1562
403/757
6
60/108
2
450/842
849/1560
Add-On after Glaze firing (690 °C/1274)
690/1274
403/757
4
60/108
1
450/842
689/1274
InLine
®
– Conventional metal-ceramic
IPS
these firing parameters are guidance values. they are valid for the Programat furnaces from Ivoclar vivadent.
Deviations (approx. +/- 10 °C/18 °F) may occur:
– Depending on the furnace generation.
– If ceramic furnaces from other manufacturers are used.
– In case of regional differences in the power supply or if several electrical devices are operatated on the same circuit.