beautypg.com

Guralp Systems CMG-DM24 User Manual

Page 41

background image

Operator’s Guide DM-24 Digitiser

Issue G January 2003

39

SENSOR MASS CONTROL

Command

Syntax

Comments

LOCK

LOCK

UNLOCK

UNLOCK

CENTRE

CENTRE

The 3 commands LOCK,
UNLOCK, and CENTRE are
simply entered at the command line.
While they are executing the system
displays the mass positions for the 3
components updated once per second
(3 seconds to cycle through the 3
components). The mass positions are
measured to 16 bits so when the
masses are locked the displayed
readings will be in the region of 32k
or -32k. When the masses are
correctly centred the readings should
be less than 1000 counts.



AUXILIARY (MUX) CHANNELS

Command

Syntax

Comments

SET-CONFIG

SET-CONFIG

See digitiser output
programming earlier



If you are programming the digitiser using the SCREAM terminal window or a
standard terminal program, you must issue the RE-BOOT command to restart the DM.


Command

Syntax

Comments

RE-BOOT

RE-BOOT
no parameters

The command prompts the
operator to confirm this
operation with ‘y’. The
system will then
automatically reset after a
delay of about 2 s.