Operator’s Guide DM-24 Digitiser

Issue G January 2003

32

There are more commands for when using the digitiser in filing mode through the
terminal connection. These allow the user to define more accurately what data the
digitiser sends from the flash. The parameters should be set before downloading.


Status-only Replay only the status blocks.

all-data (DEFAULT) Replay all sample rates.

all-times (DEFAULT) Replay all data regardless of time stamp.

Stream xxxxxx Only data with stream-id xxxxxx

nn s/s i.e. 04 s/s , Replay any streams with
specified
sample rate (overrides stream selection).

yyyy mm dd hh mm from-time Specifies start time of the selection.

yyyy mm dd hh to-time Specifies end time of the selection.

download Starts the operation with the set
parameters.

reset-flash Deletes all the data in the flash file.