beautypg.com

Gasboy CFN Plus User Manual

Page 65

background image

CFN PLUS Manual

51

Table 3-2. CFN PLUS Terminal Block - Mechanical Pump – Connections Definition

Terminal No.

Signal Name

Functional Description

34

IN USE 4 B(-)(Return)

Handle Up – AC In Use signal return - Nozzle 4

35

LOAD 1

Pump control output - Nozzle 1

36

LOAD 2

Pump control output - Nozzle 2

37

LOAD 3

Pump control output - Nozzle 3

38

LOAD 4

Pump control output - Nozzle 4

39

LINE 1

Pump control 12/24 VDC Input - Nozzle 1

40

LINE 2

Pump control 12/24 VDC Input - Nozzle 2

41

LINE 3

Pump control 12/24 VDC Input - Nozzle 3

42

LINE 4

Pump control 12/24 VDC Input - Nozzle 4

43

LINE IN (115/230V)

Input AC voltage

44

NEUTRAL IN (115/230V)

Neutral line

45 GROUND

IN

Ground

Figure 3-10 Terminal Block