Gasboy CFN Plus User Manual
Page 63

CFN PLUS Manual
49
• Power cable – In accordance with local regulations
• LAN cable – CAT5E
• RS232/485/422/Tokheim/Pulser – Communication cable, twisted pair, separately
shielded, low capacitance
N
N
O
O
T
T
E
E
The shield should be connected to Ground in one
side of the cable only, preferably on the CFN PLUS
side.
• Antenna cable - Communication cable, Twisted pair, separately shielded, low
capacitance
3
3
-
-
8
8
.
.
M
M
E
E
C
C
H
H
A
A
N
N
I
I
C
C
A
A
L
L
P
P
U
U
M
M
P
P
–
–
W
W
I
I
R
R
I
I
N
N
G
G
3-8.1. General
The wiring for mechanical pumps is provided in two modes:
• Figure 3-11 lists the wiring in the sequential order of the terminals. This table provides the
signal name and a functional description of the signal.
• Figure 3-11 shows the wiring list for connection to the Terminal, as published in the Wiring
Label added to the power protective window (see Figure 3-12). The Wiring Label follows
the physical location of the wires in the Terminal Block, as shown in Figure 3-11.
3-8.2. Mechanical Pump – Terminal Block - Pin-Out
Connections
The CFN PLUS Terminal Block connections for a Mechanical Pump are listed in the following
table.