Gasboy CFN Plus User Manual

Page 42

background image

CFN

PLUS

Manual

28

Table 2-2. CFN PLUS, Cables Type

No.

Function

Type

1

AC Power from Office

Power cable, 3x1.5 mm

2

NYY (14 AWG), in

accordance with local standards

Control to pumps (valves or engine)

In-use

signal

Pulser

Data

communication cable, 300 V RMS, 90ºC,

shielded twisted pair, oil resistant, 24 AWG,
low capacitance below 60 PF/meter similar to
Belden 9729 cable

TLG

(RS-232)

3

LAN

CAT5E, Shielded, 300 V RMS, 90ºC similar to
Belden 121700A

4

GND

Ground cable 0.4" (10.8 mm

2

)

2-6.3. Cables Routing
Route the cables from the peripherals and the Office to CFN PLUS as listed in Table 2-3 and shown
in Figure 2-3. Proceed as follows:

Table 2-3. CFN PLUS, Cables Routing

No. Functional

Description

From

Through Insert

Cable Type (*)

1

Power AC

Office

High voltage conduit

1

2 GND

Office

High

voltage

conduit

4

3

TLG

Office

Low voltage conduit

2

4

LAN

Office

Low voltage conduit

3

5

Control, Pump A

Pump A High voltage conduit

1

6

In-use, Pump A

Pump A High voltage conduit

1

7

Pulser, Pump A

Pump A Low voltage conduit

2

(*) Refer to Table 2-2.