beautypg.com

Console (console), Serial port configuration - page 8, Transaction miscellany - page 11 – Gasboy Buypass User Manual

Page 15

background image

MDE-4606B Gasboy CFN Series Buypass Credit and Debit Card Networks · August 2010

Page 11

Configuring the Site Controller

Configuration

Serial Port Configuration - Page 8

Host handler channel

The host modem port number. The default port number is none, which is set using
MODEMS.BIN.

Host router data

The 13-digit terminal ID received from your Buypass representative.

More router data


Note: This must be blank. The parameter is no longer used for Buypass

configuration.

Send requests to host
handler

Set to 24 for credit and checking

Host handler data

Two digit numbers. The default numbers are 00 20 00 00. Enter the numbers by
typing the following:
00 Enter 20 Enter 00 Enter 00 Enter 00 Enter Enter
Note: Repeat Enter as required, to exit host handler data.

• The first two digits are maintained by the MODEM.BIN program.
• The second two digit number is a hexadecimal value for the number of seconds

to allow the carrier to be received (this is called Carrier Timeout). The default 20
sets it for 32 seconds. Setting it for 10 would make it 16 seconds, 18 would be
24 seconds, 28 would be 40 seconds, and 30 would be 48 seconds.
Note: Carrier Timeout cannot be set to greater than or equal to the number of

seconds as the Verification Timeout parameter, as on

“System

Parameters (SYS_PAR)”

on

page 10

.

• The third two digit number is not used.
• The fourth two digit number is the carrier synchronization time in tenths of a

second. The range is 03 and 06. Setting it to 00 is the same as 03 (or

three-tenths of a second).

• The fifth two digit number is the time in seconds to wait for ENQ. The range is

01-30. The default is 15 seconds, which is used if the value is set to 00. Some
sites will show improved connectivity if this is set to 3 seconds.

• If setting up a Very Small Aperture Terminal (VSAT), the sixth two digit number

is required. Refer to

“Connection to a Hughes VSAT”

on

page 30

for specific

settings.

• The fifteenth two digit number is maintained by the DEBUG.BIN program (refer

to

“Troubleshooting Communications”

on

page 26

).

• The sixteenth two digit number is maintained by the DEBUG.BIN program (refer

to

“Troubleshooting Communications”

on

page 26

).

Transaction Miscellany - Page 11

Bank PIN Data Encryption Standard (DES) YES

Console (CONSOLE)

Information on the content of some of the console parameters that affect network operations
are listed below. Following are the required settings:

Console Parameter

Setting

Allow hand entry of card data

Yes

Mod 10 check on hand entered non-club cards No

POS asks for odometer on fuel sale

1 (card encoded)

POS asks for auxiliary # on fuel sale

1 (card encoded)

POS asks for odometer on merchandise sale

1 (card encoded)

POS asks for auxiliary # on merchandise sale

1 (card encoded)

The default Buypass configuration also includes parameters for accepting manually-entered
account numbers for Wright Express, Voyager, and Gulf, after the clerk presses the appropriate
network key.