Retrofit conduit, refer to, Installing retrofit conduit, Mechanical models only) – Gasboy 8700K User Manual
Page 12: Caution
![background image](https://www.manualsdir.com/files/787378/content/doc012.png)
Page 12
MDE-4512A Lamp Kit (M06227K00X) Installation Instructions for Atlas® 8700K/9100K and 8800K/9800K · June 2014
Installing Lamp Kit (M06227K00X)
Installing Lamp Kit (M06227K00X)
Installing Retrofit Conduit (Mechanical Models Only)
To install the Retrofit Conduit (021433) in mechanical models, proceed as follows:
1
At the AC Junction Box (J-box), remove the bolts securing the J-box cover and remove the
cover.
Note: Save the bolts for reassembly of the unit after the installation is complete.
2
Locate the Conduit Assembly (021433), Bushing Assembly (K49827), and the Expansion
Union (N16289-20).
3
Mount the union to one end of the conduit assembly.
4
Mount the bushing assembly in an available opening in the J-box to accommodate the conduit
assembly.
Be very careful when bending and shaping the conduit assembly. The tubing is
very easily deformed and may kink if bent in too short a radius.
CAUTION
5
Install the conduit assembly in the unit by placing the end with the mounted union into the unit
above the cross member and feeding down toward the J-box. The tubing must be carefully
bent and shaped to allow the union to fit into the bushing mounted to the J-box.
Figure 9: Installing Conduit Assembly
Union and Bushing
Cross Member
Tie-wrap
Conduit Assembly
Tie-wrap