Timeout switch – Gasboy 9120K Series Installation User Manual
Page 49

Pulse Rate
SW2-1
SW2-2
SW2-3
1
Closed
Closed
Closed
10
Open
Closed
Closed
100
Closed
Open
Closed
250
Open
Open
Closed
500
Closed
Closed
Open
None
Closed
Open
Open
None
Open
Open
Open
MDE-4567C 9120K and 9820K Series AST Pumps Installation and Operation Manual · September 2008
Page 45
CPU Switch Settings
9820K Setup and Special Features
Leading zeros are always suppressed in the hundreds and tens positions to the left of the
decimal point. When in standalone mode, positions to the right of the decimal point are
displayed based on the pulse rate selected as shown in the chart below.
Pulse Rate
Display
1:1
XXX.
10:1
XXX.X
100:1
XXX.XX
250:1
XXX.XXX
500:1
XXX.XXX
Timeout Switch
When the 9820K is in standalone mode, it will turn off an active hose if it does not detect
pulses for 4 minutes, 15 seconds. This timeout feature can be disabled by setting switch SW2-
4 to Open.
Timeout
SW2-4
Enabled
Closed
Disabled
Open