Switch sw1, Figure 6-3, Check thes – Gasboy 9120K Series Installation User Manual

Page 46: Sw1-1: baud rate, Sw1-2: mode

background image

9820K Setup and Special Features

CPU Switch Settings

Page 42

MDE-4567C 9120K and 9820K Series AST Pumps Installation and Operation Manual · September 2008

Figure 6-3: CPU PCB – Location of Switches

Switch SW1

SW1-1: Baud Rate

This switch is set to reflect the communication rate of the Gasboy RS-485 pump loop; open for
9600 baud or closed for 1200 baud. The Gasboy CFN system and TopKAT

TM

communicate at

9600 baud.

Baud Rate

SW1-1

Fuel System

9600

Open

• CFN
• TopKAT top-mount
• TopKAT electronic

1200

Closed

None currently supported

SW1-2: Mode

If the 9820K is controlled by a Gasboy CFN or TopKAT electronic fuel management system,
the switch should be open (online mode). If the 9820K is controlled by a Gasboy Series 1000
or TopKAT mechanical system, or controlled by any non-Gasboy system, or not controlled by
any fuel management system at all, the switch should be closed (standalone mode).
Note: The 9820K is shipped in standalone mode.

Mode

SW1-2

Fuel System

Online

Open

• CFN
• TopKAT top-mount
• TopKAT electronic

Standalone

Closed

• Series 1000
• TopKAT mechanical
• All non-Gasboy systems
• No fuel system