Maintenance and Troubleshooting

4-17

Sign is stuck on bright or dim.

Check Manual/Auto dimming in

Venus 1500 software.

Check light detector cable.

Check light detector for obstructions.

Replace the light detector.

Replace the controller.

4.12 Initial Operation Information

Every time the display is operated, the display will run through an initialization in
which it will display the following:

1. Product Name (Galaxy®)
2.
Display Size (Row x Column)
3.
Shading (64 Mono)
4.
Bootloader Version (OS X.XX)
5.
Firmware Number (ED13305)
6.
Firmware Revision (Rev X.XX)
7.
Hardware Address (HW:XX)
8.
Software Address (SW:XX)
9.
IP Address: ((default) 172.16.192.25)
10.
Subnet Msk: ((default) Msk: 255.255.0.0)
11.
COM1 Configuration (C1:V15) ((Modem C1:V15) If a Modem is present)
12.
COM 2 Configuration (C2:RTD)
13.
Socket 3001: (IP 3001: V15)
14.
Socket 3002: (IP 3002: RTD)
15.
Line Frequency (CLK: AUTO 60 Hz)
16.
Display Name Description (Galaxy Row x Column)

After this sequence is complete, the display will blank. A single pixel will flash in
the lower right hand corner of the display to show that the display has power, but no
messages are currently running.