beautypg.com

Troubleshooting, Troubleshooting -16, 11 troubleshooting – Daktronics AF-3197-89-RGB User Manual

Page 60

background image

Maintenance and Troubleshooting

4-16

4.11 Troubleshooting

This sub-section contains some symptoms that you may encounter with the displays.
This list does not include every possible symptom, but does represent common
situations that may occur.

Symptom/Condition Possible

Cause/Remedy

One or more LEDs on a single

module fail to light.

Replace/check cables on the module.

Replace pixel strip.

Replace the driver.

One or more LEDs on a single

module fail to turn off.

Replace/check cables on module.

Replace pixel strip.

Replace the driver.

A section of the sign is not

working. The section extends all

the way to the right side of the

sign.

Replace/check the cables.

Check power to the modules.

Replace the first driver on the left

side of the first module that is not

working.

Replace the second driver that is not

working.

Replace the power supply assembly

on the first module that is not

working.

One row of modules does not

work or is garbled.

Replace/check the cables.

Replace first driver.

Replace controller.

Check the fuses in the power

termination box.

A group of modules, which share

the same power supply

assembly, fail to work.

Check power supply voltage.

Replace the power supply assembly.

Entire sign fails to work.

Check for proper line voltage into the

power termination panel.

Check the fuse in the power

termination panel.

Check/replace the ribbon cable from

the controller to the driver.

Check the voltage settings on the

power supplies.

Verify proper use of the software in

the operation manual.

Replace the controller.

Check/replace the signal cable to the

controller.

Temperature always reads -196

degrees

Check temperature sensor

connections.

Replace the temperature sensor.

Replace the controller.

This manual is related to the following products: