Vipersat Configuration

3-32

Vipersat SLM-5650A User Guide

Percent Allocation

This parameter field appears for Hub modems only.
The Percent Allocation parameter allows adding a fixed percentage to the

channel bandwidth request to accommodate additional bandwidth requirements

which may occur after the switch is made from STDMA to SCPC mode.
Typically the default value (10%) will be sufficient, but if there may be a larger

bandwidth requirement after the switch, the percent allocation value can be

increased. In choosing a value for this allocation, future bandwidth require-

ments for the channel must be balanced against efficient bandwidth utilization.
To change this setting, enter a value from 0–100% as shown in figure 3-36.

Figure 3-36 Percent Allocation field

SCPC Step Up Threshold

This parameter field appears for Remote modems only.
The SCPC Step Up Threshold establishes the percentage of bandwidth use

that will trigger a switch up from the present SCPC rate to a higher rate to

ensure that there is sufficient bandwidth available for current conditions.
A default value (95%) is provided, but if a different threshold is desired, an

alternate value can be specified by entering a value from 0–100% as shown in

figure 3-37.
Note that this value must be greater than the value specified for the SCPC Step

Down Threshold.

Figure 3-37 SCPC Step Up Threshold field

SCPC Step Down Threshold

This menu item appears for Remote modems only.
The SCPC Step Down Threshold establishes the percentage of bandwidth use

that will trigger a switch down from the present SCPC rate to a lower rate to

ensure efficient bandwidth usage.