Chapter 3 - Using the Web Server Interface (WSI)

3-25

Vipersat Configuration

Set Remote Policies—GIR and ECM

The STDMA page for GIR and ECM Hub types allows the configuration of

each Remote for specific data switching conditions.

GIR Remotes

As shown in figure 3-26, two additional parameters—GIR and GIR Switch

Rate—are settable in the table for the GIR Remotes. Note that, above the table,

data rate and bandwidth guidelines for setting the GIR values are provided as

reference to assist the user with configuration of these parameters.
Set the Switch Rate to a value greater than the GIR to allow the Remote to be

automatically switched out of STDMA and into SCPC mode when traffic

exceeds the GIR. A switch rate of 0 (zero) will prevent the Remote from being

switched.
Click the Submit Changes button following any parameter modifications.

ECM Remotes

The SCPC Data Rate and Switch Type parameters are two additional settings

that can be configured in the table for the ECM Remotes, as shown in

figure 3-27.
Set the SCPC Data Rate to the desired value (kbps) that will be the starting point

for communications. Set the Switch Type as follows:

Type 0 (zero) corresponds to Load Switching.
Types 64 through 255 are user-defined, and must match VMS policies.

When choosing Load Switching as the switch type, the associated Remote must

have the Load Switching feature Enabled (see the section “Vipersat Switching”

on page 3-28).
Click the Submit Changes button following any parameter modifications.

Remove Remote from STDMA Group

From the STDMA Hub page, the Delete Entry feature is available as shown in

figure 3-28, allowing a Remote to be removed from the table list for this Hub

burst controller.
Enter the Index number from the table for the Remote station to be removed and

click the Delete Entry button.