Vipersat Configuration

Power Hunt

Power Hunt is a transmission power control feature for the Remote modulator

that functions while the Remote is in STDMA mode. This parameter provides

compensation for instances when the initial (baseline) power value is insuffi-

cient or during periods of impaired transmission, and assists in maintaining

return link integrity.
When a predetermined number of consecutive burst acknowledgements from

the Remote are missed at the Hub, the power output is increased in 1 dB incre-

ments, up to a maximum of 3 dB. The value specified for the Power Hunt

parameter (range is 0-3) determines the maximum power increase for this

Remote.

Figure 3-22 Power Hunt field

The Power Hunt function is disabled when the Remote switches from STDMA

to SCPC mode, where the DPC feature is then applied. However, the Power

Hunt value at the time of the switch is carried over as the initial DPC offset

value. When switching back to STDMA from SCPC mode, the last DPC offset

will be applied as the power hunt (delta) value.
A modem reboot or forced revert will clear the DPC offset and reset it to 0 dB.

Outbound IP

This parameter, which appears for all Hub configurations, displays the current

TDM Outbound IP address. This specifies the Hub device that is supplying the

TDM outbound carrier to the satellite (typically a SLM-5650A). Specifying this

address is necessary when configuring a Hub that utilizes a burst controller that

is a separate device from the TDM modem.
This address must also be defined when the DPC feature is implemented for a

network. Note that the Outbound IP address will be the same as the burst

controller address when the TDM modem and the burst controller are the same

device.
To define the TDM Outbound IP address, enter the address of the TDM

modem unit and click the Submit button. The dialog in figure 3-23 shows this

Hub parameter field.