Table c-2 dpc parameters, calculate max power, Menu, Table c-2) – Comtech EF Data SLM-5650A Vipersat User Manual
Page 128: Table c-2
Configuration
C-8
Vipersat SLM-5650A User Guide
SOTM Offset
Main;
Modulator
Display
Only
Satcom-On-The-Move hunt power adjustment
when operating in STDMA mode. When
enabled, this offset value is applied to the
BaseLine Power when switching into SCPC
mode. Used for Roaming feature.
Margin
Main;
Modulator
Display
Only
The site power margin as used in Max Power
calculation. See Calculate Max Power for more
details.
Table C-2 DPC Parameters, Calculate Max Power Menu
Parameter
Menu
Default
Description
Calibrated
Data Rate
Calculate
Max Power;
Modulator
Display
Only
The Home State or base value Data Rate from
initial configuration and commissioning.
Nominal
Power Level
Calculate
Max Power;
Modulator
Display
Only
The Home State or base value Power Level from
initial configuration and commissioning.
DPC Margin
Calculate
Max Power;
Modulator
5.0 dB
The site power Margin given by the calculated
link budget, used to provide adjustment in clear
or diminished conditions.
Max Data
Rate
Calculate
Max Power;
Modulator
1024000
bps
The site maximum Data Rate given by the
calculated link budget, used to provide stop limit
adjustment in clear or diminished conditions.
See modem specifications for valid range.
Max Code
Rate
Calculate
Max Power;
Modulator
Rate 3/4
The site maximum Code Rate given by the
calculated link budget, used to provide stop limit
adjustment in clear or diminished conditions.
See modem specifications for valid range.
Max
Modulation
Calculate
Max Power;
Modulator
QPSK
The site maximum Modulation given by the
calculated link budget, used to provide stop limit
adjustment in clear or diminished conditions.
See modem specifications for valid range.
Max FEC
Type
Calculate
Max Power;
Modulator
Undefined
The site maximum FEC Type given by the
calculated link budget, used to provide stop limit
adjustment in clear or diminished conditions.
See modem specifications for valid range.
Table C-1 DPC Parameters, Main Menu
Parameter
Menu
Default
Description