C-10

Vipersat SLM-5650A User Guide

changed from the CLI Calculate Max Power menu (figure C-5). The calculator

function is not available from the Parameter Editor because it does not contain

the information for the modem BER waterfall curves, which is vital to calculate

maximum power. Consequently, the Parameter Editor provides display-only

values for the maximum settings from when the parameter file was acquired

from the modem. Thus, this dialog (figure C-6) is labeled DPC Calibration

rather than Calculation.

Figure C-4 DPC dialog, Parameter Editor

Enable DPC

When implementing the DPC function, it is necessary to enable DPC for each

modem that will utilize this feature and any of the corresponding demodulator

devices that it may link with, as the function is a peer-to-peer protocol.

Target Eb/No

The Target Eb/No value is entered as defined in the site link budget calculations

and provides the desired signal strength for the DPC process, which is a closed

loop servomechanism. The modulator closed loop servomechanism relies on an

IP packet (message) that is generated by the corresponding receiving demodula-

tor (distant end), is sent every 30 seconds, and contains a processed E

b

/N

0