CMR-8500 DVB IP ENCAPSULATOR

Revision 2

Appendix A. Software Upgrade

MN-CMR8500

A–4

To update the CMR-8500 via FTP (using a Windows PC):

IMPORTANT

The CMR-8500 FTP server process does not support several FTP client software

programs. When updating a CMR-8500 via FTP from a Windows PC, use the FTP
commands from a command prompt (DOS window) only.

Step

Procedure

1

Verify that the “Update To” selection on the Firmware Page is correct (Slot 1, Slot 2, or
Oldest).

2

Verify that the “Boot From” selection on the Firmware Page is correct (Slot 1, Slot 2, or
Latest).

3

Verify that the update package file is on the PC, or on a network drive accessible from the
PC.

4

Open a command prompt (Select “Start”, then “run”, then type in cmd).

5

Open an FTP session to the CMR-8500. Example: “ftp 192.168.1.10

6

Set the transfer to binary mode, i.e., issue the “bin” command

7

Use the FTP “put” command to transfer the file. Example: “put cmr-8500-2_0_0.pkg

8

After the file has transferred successfully, close the FTP session using the “bye” command.

9

Once the update has completed, a reboot of the unit is required.