CMR-8500 DVB IP Encapsulator

Revision 2

Chapter 2. Installation and Initial Configuration

CMR-8500

2-2

2.3

Installation

The CMR-8500 is designed for ease of installation and configuration. Once the unit has been removed
from the packing container, please follow these instructions:

Step

Procedure

1

Place the unit into a rack with free airflow, where the LEDs can be clearly observed and with
unrestricted access to the rear panel of the unit.

2

Do NOT connect the ASI cable until the unit has been completely configured.

3

Connect the IEC 320 AC power cable to the power connection on the back of the unit.

4

Connect AC power (via the IEC 320 power cord) between a standard wall outlet and the CMR-8500.

5

Upon startup, the LEDs on the front panel illuminate as follows:

Color

Label

Description

Green

/

Red

STATUS

Red indicates error status, green indicates status ok

Green

ASI IN 1

Solid when ASI input on this port (future)

Green

ASI IN 2

Solid when ASI input on this port (future)

Green

REDUN

Redundancy indicator. Solid green unit is redundant online and flashing green is

redundant offline (backup)

Amber

FE ACT

Flashes when activity on the management interface

Amber

GE1 ACT

Flashes when activity on the GigE-1 interface

Amber

GE2 ACT

Flashes when activity on the GigE-2 interface

Amber

MGT

Solid when management connection (FTP, web or Telnet activity)

6

Connect the FE interface to the Ethernet switch to allow the CMR-8500 to be managed via a web
browser on a PC.

IMPORTANT