beautypg.com

Comtech EF Data CMR-8500 Manual User Manual

Page 52

background image

CMR-8500 DVB IP Encapsulator

Revision 2

Chapter 4. Device Management via User Interfaces

4.2.4.3 Redundancy

Note: Only CoP3 GE/GE redundancy is supported!

4.2.4.3.1

Cop3 (Gigabit Ethernet)

Figure 4-14. CMR-8500 Web Interface Redundancy Tab

Redundancy is enabled when two CMR-8500 units are configured as redundant units and able to
communicate via Ethernet connection (Management (FE) Interface). To use redundancy, connect a DB-15
to DB-15 cable (CA-0000316) between the primary and secondary CMR-8500 redundancy ports.

The configurable parameters for the Redundancy Tab are:

• GE-1 Interface:

• Other Unit’s IP Address: The IP address of the GE-1 interface on the other CMR-8500 used in

this redundant pairing.

• Other Unit’s MAC address: The MAC address of the GE-1 interface on the other CMR-8500

used in this redundant pairing.

• GE-2 Interface:

• Other Unit’s IP Address: The IP address of the GE-2 interface on the other CMR-8500 used in

this redundant pairing.

4-20