4 config | redundancy – Comtech EF Data LPOD User Manual
Page 87

LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter
MN-LPOD
Ethernet-based Remote Product Management
Revision 10
4–23
4.5.4.3.4
Config | Redundancy
Appendix A. 1:1 REDUNDANCY
Use this page to configure the LPOD’s Redundancy Switch Mode.
Figure 4-9. Config | Redundancy Page
Click [Refresh] (at the top of the page) to update the page appearance to the current operating
configuration.
Redundancy
To update the page to the current redundancy configuration: Click [Refresh].
Enable Redundancy Switch Mode
Use the drop-down list to select the Switch Mode as follows:
• Off – Disables redundancy.
• 1:1 Red TX – Enables 1:1 redundancy with transmit switch control.
• 1:1 Red TX+RX – Enables 1:1 redundancy with transmit and receive switch control.
• Manual: Enables manual redundancy mode.
Click [Change] once the desired mode selection has been made.
Online Status
This read-only section displays the active status for the unit as either Online or Offline.
Force Online
To force a unit to go active (online): Click [Force Online].