2 config | lnb – Comtech EF Data LPOD User Manual

Page 84

background image

LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter

MN-LPOD

Ethernet-based Remote Product Management

Revision 10

4–20

4.5.4.3.2

Config | LNB

Use this page to configure Low-Noise Block Downconverter parameters, and display the LNB

status for L-Band operation.

Figure 4-7. Config | LNB Page

Click [Refresh] (at the top of the page) to update the page appearance to the current operating

configuration.

LNB Config

LNB Current Source – Use the drop-down list to select this feature as either Enabled or

Disabled.

Switch Bias Tee – Use the drop-down list to select either Through State (unmute LNB) or Off

State (mute LNB).

LNB Current Window – Use the drop-down list to select this feature as either Enabled or

Disabled.

LNB Current Window (%) – This field defines the size of the LNB Current Window, and

determines the fault thresholds for the LNB current draw.

Any LNB current reading that is outside the window may generate an alarm, a fault, or may

be masked entirely depending on the state of the user-configured fault mask (see the MSK

command syntax in Chapter 5. SERIAL-BASED REMOTE PRODUCT MANAGEMENT for more

information).

For example: If the LNB draws 100mA, and the LNB current fault window is set to the

default value of 30(%), then the allowable current draw for the LNB will be from 70 mA

minimum to 130 mA maximum because the window is +/- 30% centered on the calibrated

LNB current draw.

Click [Submit] to save any changes.