beautypg.com

2 functional description, 3 features, 1 the solid-state advantage – Comtech EF Data LPOD User Manual

Page 20: 2 enhanced standard features, 3 built-in redundancy controller

background image

LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)

MN-LPOD

Introduction

Revision 10

1–2

1.2

Functional Description

The compact size and weight of the LPOD lends itself to any installation with limited available

mounting space. These include ship-borne antenna systems, small “flyaway” systems, and

Satellite News Gathering (SNG) installations. The addition of the optional internal reference and

LNB bias T facilitates multi-carrier and redundant operations required of small-to medium-sized

hub installations.

As shown in Figure 1-1, Comtech EF Data’s LPOD is available in three models: the PS 1, PS 1.5

and PS 2. Each LPOD consists of a CEFD SSPA module with the Monitor/Control Processor (MCP),

a power supply, and a fan assembly. The amplifier features a Comtech EF Data low loss

combining technique and MCP-based temperature-versus-gain compensation.

The PS 1 and PS 1.5 models are always configured as a BUC/SSPA (L-Band in, RF out) with

available power levels to 100W; the PS 2 version can be configured as an integrated BUC/SSPA

or solely as an SSPA (RF in, RF out) at power levels to 250W.

1.3

Features

1.3.1

The Solid-State Advantage

The LPOD is constructed with highly reliable gallium arsenide field-effect transistors (GaAs FETs).

With third-order intermodulation products that are 4 to 6 dB better than TWT ratings, the CEFD

unit replaces TWTs with saturated power levels of up to twice the LPOD’s rated output. The

LPODs also provide mean time between failures (MTBF) that is four to five times greater than

the typical TWT MTBF.

1.3.2

Enhanced Standard Features

The LPOD comes equipped with useful features that other manufacturers offer only as options.

Included in the base price are temperature compensation, sample ports (on the PS 2 only),

power monitor, power factor corrected supply, and full remote monitor and control (M&C)

capabilities (including Ethernet and serial).

1.3.3

Built-in Redundancy Controller

The LPOD has the ability to function as a 1:1 (one backup for one primary) redundant controller in

a redundant mode without the use of an external device. The optional redundancy configuration is

implemented by attaching a ganged waveguide/coax transfer switch(es) to the input and output

connectors of the amplifiers, using a combination coaxial cable and waveguide kit.

When the backup LPOD is commanded into redundant mode, it monitors the online LPOD for

faults and status, and automatically maintains a configuration based on the online unit.

A faulted online unit may be disconnected and replaced without affecting the online power

amplifier.