LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)

MN-LPOD

Serial-based Remote Product Management

Revision 10

5–26

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

Retrieve Alarm

Status

N/A

168 bytes

Query only.

Returns the alarm status of the unit, where:

OK = no fault condition,

FT = faulted,

AL = alarm,

YS = Yes,

NO = No,

MS = masked,

?? = invalid due to hardware failure,

NA = not applicable because hardware/options not installed.

Example:

<1/RAS?’cr’

>0001/RAS=’cr’

P24V1=OK’cr’ +24V power supply

P24V2=OK’cr’ +24V switch pwr supply

LNBVT=OK’cr’ +13/18V LNB power supply

P13VT=OK’cr’ +13.5V power supply

P10V1=OK’cr’ +10V power supply

A10V1=OK’cr’ +10V1 RF supply

A10V2=OK’cr’ +10V2 RF supply

P7V8T=OK’cr’ +7.8V power supply

P5V8T=OK’cr’ +5.8V power supply

P2V5T=OK’cr’ +2.5V power supply

P1V2T=OK’cr’ +1.2V power supply

N5V8T=OK’cr’ -5.8V power supply

FANR1=OK’cr’ Fan 1 speed

FANR2=OK’cr’ Fan 2 speed

ATEMP=OK’cr’ Amplifier temperature

SHTDN=OK’cr’ Over-temp shutdown

IICST=OK’cr’ I2C bus status

FWPWR=OK’cr’ Forward power in dBm

CHKSM=OK’cr’ Flash checksum

FPGAD=OK’cr’ FPGA done status

BUCLD=OK’cr’ BUC lock detect

REFLD=OK’cr’ Reference lock detect

LNBCS=OK’cr’ LNB current status

SWITC=OK’cr’ Waveguide switch position status

RDLNK=OK’cr’ Redundant link status

TRMST=YS’cr’’lf’ Terminal Status

Note: LNBVT, A10V1, A10V2, FANR1, FANR2, BUCLD, REFLD, LNBCS, SWITC and RDLNK will only appear

in the list if the appropriate model / options have been selected / installed.

RAS=

RAS?

RAS=x….x

(See Description of

Arguments)