LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)

MN-LPOD

Introduction

Revision 10

1–7

1.4.7

Block Up Converter (BUC) Input

The LPOD translates an L-Band input carrier to the desired output frequency (C-, X-, or Ku-Band).

LO frequencies are as follows:

BUC C, Ku, X LO Frequencies

Band

Frequency

LO Frequency

Inverting

C-Band

5850 to 6650 MHz

4900 MHz

No

5950 to 6700 MHz

5000 MHz

No

Insat C-Band

6725 to 7025 MHz

5760 MHz

No

X-Band

7900 to 8400 MHz

6950 MHz

No

Ku-Band

14.00 to 14.50 GHz

13.050 GHz

No

Ku-Band-W

13.75 to 14.50 GHz

12.800 GHz

No

Unlike most BUCs, no DC bias voltage should be provided on the center conductor of the L-Band

coax. In addition, the LPOD is available with an internal 10 MHz reference. As, such, no 10 MHz

reference is required on the center conductor of the L-Band coax. If a reference is provided on

the coax, the internal reference will detect and lock to it.