LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)

MN-LPOD

Appendix A

Revision 10

A–5

since there are no waveguide switches monitored and controlled by the unit in standalone

mode.

Only the offline unit is allowed to initiate a redundant switchover by throwing the waveguide

switches. The offline unit will initiate a redundant switchover if any of the following conditions

are met:

Online unit faulted, and offline unit is not faulted.

Inter-unit redundant link established, and then timed out.

Mismatched waveguide switch condition is detected.

Unit is forced online through a remote command.

If the unit has offline mute (OFM) enabled, then the unit will mute the RF output when it is

offline. The OFM state also affects the bias tee switch position, because the bias tee switch

serves as the unit’s Rx path mute, so it is tied to the mute state (MUT) of the unit while the unit

is running in redundant mode (i.e., if MUT=1 then SBT=0, and if MUT=0 then SBT=1). If the user

tries to change the bias tee switch position while redundant mode is enabled a mode error will

result.

A.3.2.1 Applicable Serial-Based Redundancy Commands and Queries

See Chapter 5. SERIAL-BASED REMOTE PRODUCT MANAGEMENT for detailed

information about the remote commands and queries specified in this section.

The serial remote commands and queries applicable to redundancy operations are as follows:

Remote Command Meaning

Functional Description

RED

Redundancy Online/Offline Reports the appropriate unit’s online/offline status. Also used

to force a unit to go active (online).

ESW

Enable Switch Mode

Puts the unit into redundancy or standalone (manual) mode.

AFR

Auto Fault Recovery

Sets the latching state of faults. Either they will latch to the

faulted state or they will recover automatically.

AOF

Attenuation Offset

Individual attenuation command, used to adjust out small

differences in power levels of different amplifier.