5 summary of specifications, 1 characteristics, 5 summary of specifications 1.5.1 characteristics – Comtech EF Data LPOD User Manual
Page 26
LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)
MN-LPOD
Introduction
Revision 10
1–8
1.5
Summary of Specifications
1.5.1
Characteristics
IF Input Frequency
Note 1
RF Output Frequency
950 – 1525 MHz
5.850 – 6.425 GHz
950 – 1750 MHz
5.850 – 6.650 GHz (optional)
950 – 1825 MHz
5.850 – 6.725 GHz (optional)
965 – 1265 MHz
6.725 – 7.025 GHz
950 – 1450 MHz
7.900 – 8.400 GHz
950 – 1450 MHz
14.00 – 14.50 GHz
950 – 1750 MHz
13.75 – 14.50 GHz (optional)
Model
Psat (Typical)
P1dB (Guaranteed)
Note 2
PS1-25C,X
44 dBm (25 W)
43 dBm (20 W)
PS1-32C,X
45 dBm (32 W)
44 dBm (25 W)
PS1-40C,X
46 dBm (40 W)
45 dBm (32 W)
PS1-50C,X
47 dBm (50 W)
46 dBm (40 W)
PS1-60C,X
48 dBm (60 W)
47 dBm (50 W)
PS1-20Ku
43 dBm (20 W)
42 dBm (16 W)
PS1-32Ku
45 dBm (32 W)
44 dBm (25 W)
PS1-40Ku
46 dBm (40 W)
45 dBm (32 W)
PS1.5-75C,X
48.6 dBm (75 W)
48 dBm (60 W)
PS1.5-80C,X
49 dBm (80 W)
48.5 dBm (70 W)
PS1.5-100C,X
50 dBm (100 W)
49 dBm (80 W)
PS1.5-110C,X
50.4 dBm (110 W)
49.5 dBm (90 W)
PS1.5 or PS2-125C,X
51 dBm (125 W)
50 dBm (100 W)
PS1.5-50Ku
47 dBm (50 W)
46 dBm (40 W)
PS1.5-60Ku
48 dBm (60 W)
47 dBm (50 W)
PS2-150C,X
51.8 dBm (150 W)
51 dBm (125 W)
PS2-200C,X
53 dBm (200 W)
52.5 dBm (175 W)
PS2-250C,X
54 dBm (250 W)
53 dBm (200 W)
PS2-100Ku
50 dBm (100 W)
49 dBm (80 W)
PS2-125Ku
51 dBm (125 W)
50 dBm (100 W)
Notes:
1. PS 2 Models available as SSPAs only, without internal L-Band BUC (Freq RF in = Freq RF out).
2. Allow 1 dB degradation from 13.75 to 14.0 GHz and 6425 to 6725 MHz.
Gain Min (Typical)
70 (75 dB)
Input Power Supply Requirements
90-264 VAC, 47-63 Hz, Power Factor Corrected, .96 (typical)
(48 VDC optional)
Max IF Input level (no damage)
+10 dBm
Gain Adjust
20 dB in 0.25 dB steps
Gain Flatness
± 1.5 dB full band (optional ± 2.0 dB full band (-50° to +55°C))
± 0.30 dB per 40 MHz (optional ± 0.50 dB per 40 MHz (-50° to
+55°C)
Gain variation over temp
±1.5 dB max, -40° to +55°C (optional ± 2.0 dB max (-50° to
+55°C))