LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)

MN-LPOD

Serial-based Remote Product Management

Revision 10

5–15

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

Calibrate LNB

Current

CLC=

none

Command or Query.

Sets or returns, as a reference point, the value of the LNB Current Supply (in mA) in the form xxx.x.

Default value: 000.0

The LNB current alarm point is then determined by the calibrated LNB reference point, and the LNB current window

setting (see LCW command).

Note: this command will return a mode error if the LNB current source output has not been enabled first (see

LCS command).

Example: <1/CLC=’cr’

>0001/CLC=’cr’’lf’

The CLC query will return the value that was stored during the LNB current calibration.

Example: <1/CLC?’cr’

>0001/CLC=xxx.x where xxx.x is the calibrated LNB current value in mA.

CLC=

CLC?

CLC*

CLC?

CLC=xxx.x

(See Description of

Arguments)

Clear Statistics

Log

CSL=

1 byte

Command only.

Clears the statistics log entries. This command takes no arguments.

Example:

<1/CSL=1’cr’

>0001/CSL=’cr’’lf’

CSL=

CSL?

CSL*

N/A

CSL=

Concise Utility

Status

E

N/A

15 bytes

Query only.

Returns the Maintenance status of the unit, response is semicolon delimited, in the form aaaa;bbbbb;ccc where:

aaaa = Remote Unit Address

bbbbb = Remote Baud Rate

ccc = Reference oscillator tuning voltage DAC value (see Note)

Note: ccc is only present if a reference oscillator is installed.

Example:

<1/CUS?’cr’

>0001/CUS=aaaa;bbbbb;ccc;’cr’’lf’

CUS=

CUS?

CUS=x….x

(See Description of

Arguments)