beautypg.com

Comtech EF Data LPOD User Manual

Page 128

background image

LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)

MN-LPOD

Serial-based Remote Product Management

Revision 10

5–28

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

Reference

Oscillator Tuning

REF=

3 bytes

Command or Query.

Sets or returns the reference oscillator tuning voltage adjustment by sending a DAC value in the form xxx,

where:

xxx = is a numeric value from 0 to 255.

Default value: 087

Note: This command sets the DAC value, but the actual Reference Oscillator tuning voltage can be monitored

using the RMS command.

Example: <1/REF=087’cr’

>0001/REF=’cr’’lf’

REF=

REF?

REF*

REF?

REF=xxx

(See Description of

Arguments)

Retrieve

Equipment Type

E

N/A

22 bytes

Query only.

Returns a string indicating the Model Number and the version of the M&C firmware installed in the unit.

Example: <1/RET?’cr’

>0001/RET=PS2053-5967-C REF BUC VER: 1.5.2’cr’’lf’

RET=

RET?

RET=x….x

(See Description of

Arguments)

RF Power FET

Current Status

N/A

variable length

depending on

the number of

FETs installed

in the RF

amplifier

Query only.

Returns all FET currents in the form xx.x when the value is >1 Amp, or xxx when the value is < 1 AMP

Example: <1/RFS? ’cr’

>0001/RFS=’cr’

Q01=.xxx’cr’

Q02=.xxx’cr’

Q03=xx.x’cr’

Q04=xx.x’cr’

Q05=xx.x’cr’

Q06=xx.x’cr’

Q07=xx.x’cr’

Q08=xx.x’cr’

Q09=xx.x’cr’

Q10=xx.x’cr’

Q11=xx.x’cr’

Q12=xx.x’cr’

Q13=xx.x’cr’

Q14=xx.x’cr’

Q15=xx.x’cr’

Q16=xx.x’cr’’lf’

RFS=

RFS?

RFS=x….x

(See Description of

Arguments)