Chapter 5. serial-based remote product management, 1 overview, 2 key operational parameters – Comtech EF Data LPOD User Manual
Page 101: 1 rf input level
5–1
Chapter 5. SERIAL-BASED REMOTE PRODUCT
MANAGEMENT
5.1
Overview
Serial-based remote product management of Comtech EF Data’s LPOD family of Outdoor Amplifiers / Block Up Converters (BUCs) is
available using the LPOD’s ‘J6 | COM 1’ port. Some key parameters and procedures and their associated remote commands and queries
are summarized, followed by detailed instructions for use of the serial remote control communication command and query interface.
5.2
Key Operational Parameters
For detailed information about the remote commands and queries mentioned in this section, see Sect. 5.4 Remote Commands and
Queries in this chapter.
5.2.1
RF Input Level
The required RF input level to reach the full rated output power of the SSPA is determined by the individual amplifier maximum gain and
power rating.
For Example: If the test data of an SSPA rated for 250W (54 dBm) indicated a gain of 75 dB, then a signal of 54 dBm – 75 dB = -21 dBm
would approximately give the rated output power.