LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter (BUC)

MN-LPOD

Serial-based Remote Product Management

Revision 10

5–36

Parameter Type

Command

(Instruction

Code and

Qualifier)

Arguments

for Command

or Response

to Query

Description of Arguments

(Note that all arguments are printable ASCII characters)

Response to

Command

(Target to

Controller)

Query

(Instruction

Code and

Qualifier)

Response to Query

(Target to

Controller)

Terminal Status

Change

N/A

1 byte

Query only.

Indicates if there has been a change in the configuration since the last time a command was issued, in the form

x, where:

0 = no status change

1 = there has been a status change.

A status change is defined as any time a parameter is changed, such as when command that changes a value is

successfully executed. A status change also results when there is a redundant switchover, or a fault condition.

A query does not set the status change flag. The status change flag is cleared after being read.

Example: <1/TSC?’cr’

>0001/TSC=0’cr’’lf’

TSC=

TSC?

TSC=x

(See Description of

Arguments)

External

Reference Mute

O

XRM=

1 byte

numeric

Command or Query.

Sets or returns the external reference mute state in the form x, where:

0 = Disable

1 = Enable (see Note)

Note: To enable this command, the internal reference oscillator option must be installed; otherwise, a mode

error will result. A hardware mute condition generated by the XRM mute is one of the conditions that can cause

the MUT command to return MUT=2.

When enabled, the unit will mute if an external reference oscillator is not detected.

Example: <1/XRM=1’cr’

XRM=

XRM?

MSK*

XRM?

XRM=x

(See Description of

Arguments)