4–19
Amplifier
•
Amplifier – Use the drop-down list to select the amplifier as either On or Off.
•
Attenuation (dB) – Enter a valid attenuation level (00.00 to 20.00 dB) in 0.25 dB steps.
•
Attenuation Offset – Enter a valid value, in dB, for the attenuation offset.
•
Fault Recovery – Use the drop-down list to select Fault Recovery as either Automatic or
Manual.
•
Mute – Use the drop-down list to select the Mute function as either Enabled or Disabled.
•
AUX Mute – Use the drop-down list to select the Auxiliary Mute Mode as either Enabled or
Disabled.
•
Offline Mute – Use the drop-down list to select the Offline Mute function as Enabled,
Disabled, MuteRx, MuteTx, MuteRx+LNB, or MuteTx+LNB.
Click [Change Configuration] to save any changes. Otherwise, click [Reset] to revert to the
previously assigned Amplifier settings.
Reference
•
Ref Freq Adjust – Enter a numeric value from 0 to 255 to adjust the reference oscillator
tuning voltage. The default value is set to 87.
• Ext Ref Mute – Use the drop-down list to select the Eexternal Reference Not Present Mute
Mode as either Enabled or Disabled.
Click [Change Configuration] to save any changes. Otherwise, click [Reset] to revert to the
previously assigned Reference settings.
Low Power Forward Threshold (dBm)
Use this field to set the threshold value, in dBm, for the low forward power alarm/fault. When
the forward power monitor is set to Alarm or Fault instead of the factory default of Mask, and
the forward power drops below the specified value, the alarm/fault is indicated.
Setting this parameter to the default value of 00.00 effectively disables the threshold.
Click [Change] to save any changes. Otherwise, click [Reset] to revert to the previously assigned
Low Power Forward Threshold setting.
FSK Address
Use this field to set the FSK (Frequency Shift Keying) Address from 01 to 15. Click [Change] to