LPOD C-, X-, or Ku-Band Outdoor Amplifier / Block Up Converter

MN-LPOD

Ethernet-based Remote Product Management

Revision 10

4–19

Amplifier

Amplifier – Use the drop-down list to select the amplifier as either On or Off.

Attenuation (dB) – Enter a valid attenuation level (00.00 to 20.00 dB) in 0.25 dB steps.

Attenuation Offset – Enter a valid value, in dB, for the attenuation offset.


Fault Recovery – Use the drop-down list to select Fault Recovery as either Automatic or

Manual.

Mute – Use the drop-down list to select the Mute function as either Enabled or Disabled.


AUX Mute – Use the drop-down list to select the Auxiliary Mute Mode as either Enabled or

Disabled.


Offline Mute – Use the drop-down list to select the Offline Mute function as Enabled,

Disabled, MuteRx, MuteTx, MuteRx+LNB, or MuteTx+LNB.

Click [Change Configuration] to save any changes. Otherwise, click [Reset] to revert to the

previously assigned Amplifier settings.

Reference

Ref Freq Adjust – Enter a numeric value from 0 to 255 to adjust the reference oscillator

tuning voltage. The default value is set to 87.

Ext Ref Mute – Use the drop-down list to select the Eexternal Reference Not Present Mute

Mode as either Enabled or Disabled.

Click [Change Configuration] to save any changes. Otherwise, click [Reset] to revert to the

previously assigned Reference settings.

Low Power Forward Threshold (dBm)

Use this field to set the threshold value, in dBm, for the low forward power alarm/fault. When

the forward power monitor is set to Alarm or Fault instead of the factory default of Mask, and

the forward power drops below the specified value, the alarm/fault is indicated.

Setting this parameter to the default value of 00.00 effectively disables the threshold.

Click [Change] to save any changes. Otherwise, click [Reset] to revert to the previously assigned

Low Power Forward Threshold setting.

FSK Address

Use this field to set the FSK (Frequency Shift Keying) Address from 01 to 15. Click [Change] to

save any changes. Otherwise, click [Reset] to revert to the previously assigned FSK Address.