beautypg.com

2 remote baud rate, 3 remote address – Comtech EF Data SMS-458B User Manual

Page 63

background image

SMS-458B Modem Protection Switch

Revision 2

Theory of Operation

MN/SMS458B.IOM

4–3

4.1.2.2

Remote Baud Rate

The 8-position switch pack SP1 on the M&C module programs the external remote serial
communications baud rate and parity. Set the switches to ON (nearer the PCB) or OFF
(away from the PCB) to select parity and baud rate.

SP1 switch position 1 (SP1-1) sets the parity:

• OFF = even parity
• ON = odd parity


SP1 switch positions 2, 3, and 4 (SP1-2, SP1-3, and SP1-4) set the baud rate as follows:

Baud

SP1-2

SP1-3

SP1-4

110 ON ON ON
150 ON ON OFF
300 ON OFF

ON

600 ON OFF

OFF

1200 OFF ON ON
2400 OFF ON OFF
4800 OFF OFF ON
9600

OFF OFF OFF

4.1.2.3 Remote

Address

The switch connects to an

EIA-

485 remote communication link. To communicate on this

link, each switch and modem must have a unique address between 1 and 255.

Note: “0” cannot be a device address, as it is the global address for all devices.

To program an address, use the 8-position switch pack, SP2, on the M&C module.
Addresses are binary coded numbers:

• Switch position 1 (SP2-1) is the most significant bit.
• Switch position 8 (SP2-8) is the least significant bit.