beautypg.com

Comtech EF Data SMS-458B User Manual

Page 56

background image

SMS-458B Modem Protection Switch

Revision 2

Operation

MN/SMS458B.IOM

3–20

HAS THE

VERIFY TIMER

TIMED OUT?

VERIFY THE

CONFIGURATION

OF THE NEXT MOD.

(SERIAL REMOTE

NOT AVAILABLE)

YES

ARE ANY

PRIMES

FLT’D?

ARE THE

B/U (s) ON

STAND-BY?

ARE THE

FLT’D

PRIMES

B/U’D?

PUT FLT’D

PRIMES IN PRIORITY
ORDER. START WITH

HIGHEST PRIORITY.

IS THIS

FLT’D

PRIME B/U’D?

IS A

B/U

AVAILABLE?

IS

THE B/U

ON STAND-BY

FOR THIS

PRIME?

VERIFY B/U

CONFIGURATION.

UPDATE IF

NECESSARY.

(SERIAL REMOTE

NOT AVAILABLE)

IS THE

B/U MOD

FLT’D?

HAS

THE 100 ms

TIMER TIMED

OUT?

ARE

OTHER

PRIMES

FLT’D?

PROGRAM B/U (s)
FOR HIGHEST
PRIORITY CHANNEL(s).
(SERIAL REMOTE NOT
AVAILABLE)

PLACE B/U (s) IN
STAND-BY MODE.
INDICATE WITH “-” ON
FRONT PANEL

IS A

LOWER

PRIOIRTY PRIME

B/U’D?

IS A

NON-FLT’D

PRIME B/U’D?

PROGRAM B/U

WITH THE

CONFIGURATION

FOR THIS PRIME.
(SERIAL REMOTE

NOT AVAILABLE)

WAIT FOR ALL

APPLICABLE TIMERS.

INDICATE PRIME

WITH “#” ON

FRONT PANEL

IS THE

PRIME STILL

FLT’D?

PLACE B/U ON-LINE

FOR FLT’D PRIME

WITH “->“ ON

FRONT PANEL.

GO TO NEXT

FLT’D PRIME IN THE

PRIORITY ORDER.

MOD AUTO MODE

NO

NO

YES

NO

YES

YES

NO

NO

NO

NO

YES

YES

YES

NO

YES

NO

NO

YES

YES

YES

YES

NO

YES

NO

NO

Figure 3-3. SMS-458B Switching Algorithm Flow Chart Demodulator


MOD