B.12status commands/responses, B.12.1configuration status, B.12 – Comtech EF Data SMS-458B User Manual
Page 115

SMS-458B Modem Protection Switch
Revision 2
Remote Control Specification
MN/SMS458B.IOM
B–7
B.12
Status Commands/Responses
B.12.1 Configuration
Status
Prime
Modulator
Configuration
Status
Command:
Response:
MA_yyy’cr’
MP_y’cr’
MD_yyy.y’cr’
ADD_yyy’cr’
CU_yyy’cr’
CUA_yyy’cr’’lf’]
Where:
Mod Active (Yes/No)
Mod Priority (1, 2, or 3)
Mod Online Delay
Modem Address
Channel Unit Active
Channel Unit Address (This parameter is returned only
if the channel unit is active (CU_YES)
The modulator configuration status command causes a
block of data to be returned by switch. The block of data
reflects the stored configuration of the modulator selected.
Backup
Modulator
Configuration
Status
Command:
Response:
MA_yyy’cr’
ADD_yyy’cr’
CU_yyy’cr’
CUA_yyy’cr’’lf’]
Where:
x = 1 or 2 (backup modem number)
Mod Active (Yes/No)
Mod Priority (1, 2, or 3)
Mod Online Delay
Modem Address
Channel Unit Active
Channel Unit Address (This parameter is returned only
if the channel unit is active (CU_YES)
The modulator configuration status command causes a
block of data to be returned by switch. The block of data
reflects the stored configuration of the modulator selected.
Prime
Demodulator
Configuration
Status
Command:
Response:
DA_yyy’cr’
DP_y’cr’
DT_y’cr’
DD_yyy.y’cr’
ADD_yyy’cr’
CU_yyy’cr’
CUA_yyy’cr’’lf’]
Where:
Demod Active (Yes/No)
Demod Priority (1, 2, or 3)
Demod Transponder
Demod Delay
Modem Address
Channel Unit Active
Channel Unit Address (This parameter is returned only
if the channel unit is active (CU_YES)
The demodulator configuration status command causes a
block of data to be returned by switch. The block of data
reflects the stored configuration of the modulator selected.
Backup
Demodulator
Configuration
Status
Command:
Response:
DA_yyy’cr’
ADD_yyy’cr’
CU_yyy’cr’
CUA_yyy’cr’’lf’
Where:
Demod Active (Yes/No)
Modem Address
Channel Unit Active
Channel Unit Address (This parameter is returned only
if the channel unit is active (CU_YES)
The demodulator configuration status command causes a
block of data to be returned by switch. The block of data
reflects the stored configuration of the modulator selected.