B.9demodulator configuration commands/responses – Comtech EF Data SMS-458B User Manual

Page 113

background image

SMS-458B Modem Protection Switch

Revision 2

Remote Control Specification

MN/SMS458B.IOM

B–5

B.9 Demodulator

Configuration

Commands/Responses

B.9.1

Prime Demodulator Configuration Commands/Responses

Demodulator
Active

Command:
Response:

Status:
Response:

>add/DA_x_yyy'cr''lf']

>add/DA_x_yyy'cr''lf']

Where:

x = 1 to 4 (prime demodulator number)

yyy = Yes or No

Demodulator
Priority

Command:
Response:

Status:
Response:

>add/DP_x_y'cr''lf']

>add/DP_x_y'cr''lf']

Where:

x = 1 , 2, 3, or 4

y = 1, 2, 3, or 4


Where

1 = High

2 = Medium

3 = Low

Demodulator
Transponder

Command:
Response:

Status:
Response:

>add/DT_x_y'cr''lf']

>add/DT_x_y'cr''lf']

Where: x = 1 to 4 (prime demodulator number)

y = 1, 2, 3, or 4 (transponder number, 4 transponder

option)

y = 1, 2, 3, 4, 5, 6, or 7 (transponder number, 7

transponder-

option)


Note: See ‘DTO_ ‘ command for definition of downlink
transponder option.

Demodulator
Online Delay

Status
Response:

>add/DD_x_yyy.y'cr''lf']

>add/DD_x_yyy.y'cr''lf']

Where: x = 1 , 2, 3, or 4 (Prime demodulator number)

yyy.y = 0.5 to 127 (time in increments of 0.5

seconds)
Auto
None

B.10

Backup Demodulator Configuration Commands/Responses

Backup
Demodulator
Active

Command:
Response:

Status:
Response:

>add/DA_Bx_yyy'cr''lf']

>add/DA_Bx_yyy'cr''lf']

Where: x = 1 or 2 (Backup demodulator number)

yyy = Yes or No


Note: Backup No. 2 can not be active if the downlink
transponder option is specified to be 7. See the ‘DTO_”
command.