Front panel led states during system startup -31, Table 4-4 – Comtech EF Data SDM-9220 User Manual
Page 73
Hardware Installation
Memotec Inc.
4-31
NOTE:
If the
PWR
LED does not light up or the
STATUS
LED is red at the end of
this sequence, the unit may be faulty. Contact Technical Support for assis-
tance (see
“Technical Support” on page 1-8
). See also
Stage
PWR
ST
AL
Current Status of the SDM-9220/9230
1
green
blink
blink
Quick hardware test by the bootstrap. Blink-
ing and frequent changes of the STATUS
and ALARM LEDs occur during this stage
2
green
red
green Hardware initialization by the bootstrap
3
green
red
off
Bootstrap is running. Preparing to start the
boot sector
4
green amber
off
Boot sector is running. Validating the applica-
tion
5
green amber amber Boot sector is running. Decompressing the
application
6
green
off
off
Application has started from a power-on
red
Application has started from a software reset
7
green
green
off
Application has started from a power-on; at
least one link is up
red
Application has started from a software reset;
at least one link is up
Table 4-4: Front Panel LED States During System Startup